Thermal imager TKTI 20 SKF - new version
New version - characteristic:
Four optional temperature ranges as standard:
- Standard
Temperature range: -10 °C to 250 °C
Application, typical use: predictive and preventive maintenance, control of mechanical and electrical devices, production monitoring, control of pumps and fans, generally in an industrial environment.
This range was used in the previous version of the imager TKTI 20.
- Buildings
Temperature range: -20 °C to 125 °C (sensitivity <= 0.05 °C, enables imaging of the smallest temperature differences)
Application, typical use: control of structures, audits of energy losses, industrial cooling systems, maintenance of structures and equipment service.
- High range
Temperature range: 200 °C to 500 °C without the use of a special filter
- Extended temperature range
Temperature range: 200 °C to 900 °C with the use of a special filter
Application (for 3 and 4), typical use: petrochemical industry, glassworks, cement plants, steelworks
After the imager is turned on, the selected temperature range will appear for several seconds, and may be simply changed by the user in the Infrared Settings menu.
The new thermal imager TKTI 20 is supplied in a highly resistant case ensuring sufficient protection.